<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15162</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: timeout moving bay &lt;bay#&gt; shutter cylinder
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check for mechanical interferance,
Check alignment of shutter cylinder Hall effect sensors, and cabling.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume, Open side panels and check that shutter is not obstructed.
Call Creo service if problem persists.
</text></DescriptionText>
</OperatorAction>
<Cause>
Bay shutter closed sensor was not detected within "shutter_delay" while closing, or
bay shutter open sensor was not detected within "shutter_delay" while opening.  If opening
when this error occurs then the firmware will close it again, (set verbose 1 for message)
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_nss.xml</LinkAddress><LinkTitle>NVS: al nss</LinkTitle></Link>
<Link><LinkAddress>../nvs/aldly_cal_shut.xml</LinkAddress><LinkTitle>NVS: aldly shut</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:53 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/platesetter_3244/content/troubleshooting/15162.html</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>